Fuji Electric Fvr-e7s Manual
Discontinued Products Below you will find a list of Fuji Electric products which have been discontinued as well as their documentation ready for download in all available languages. In case you need any further documentation or support, please do not hesitate to contact us directly: FRN-C1 • • • • • • • • • • • FVR-C9S • • FVR-C11S • • • • FVR-E7S • • FVR-E9S • • • • FVR-E11S • • • • • • • • • • FVR-G5S • • • FVR-G7S • • • • FRN-G9S • • FRN-G11S • • • • • • • • • • • • • FRN-VG5S • FRN-VG7S • • Faldic-W • •.
Dell Inspiron 1420 Bcm2045 Driver. • FVR-C9S-7UX Instruction Manual FVR-C9S-7UX Drive Series Single-phase 240 V AC Input Type. • • Please make sure that this instruction manual accompanies the drive to the end user. • Keep this instruction manual so that it will always be available for the duration of the drive’s operating life. • Product specifications are subject to change without notice. • Thank you for purchasing the Fuji “FVR-C9S” drive marketed by GE Fuji Drives USA, Inc. This instruction manual is included with the drive and equipment and is provided for the conve- nience of the end user. Please be sure it accompanies the drive.
Drives & Automation. Fuji Electric delivers high performance inverters that offer automatically controlled motor operations and operating speeds for a wide variety of. FUJI FVR E9S Solicitud de manual de. FUJI ELECTRIC RSM-9LA Manual de. FUJI FVR E7S 7EX GUIA USUARIO FUJI FVR E7S 7EX GUIA USUARIO FUJI -FVR.
Required for CE Certification. WIRING WARNING: FIRE AND ELECTRIC SHOCK HAZARD. When connecting the drive to a power supply, be sure to connect it via a circuit breaker, a leakage current breaker or a fuse, otherwise fires may result.
Download Autocad Electrical Iec Symbol Library Download. • OPERATION WARNING: ELECTRIC SHOCK HAZARD Always install the drive cover before turning on the power supply. In addition, do not remove the drive cover while the power is on. Failure to observe these precautions may result in electric shocks. Do not operate any of the switches with wet hands, otherwise electric shocks may result. • FVRF12C9S-7UX FVRF25C9S-7UX FVRF50C9S-7UX FVR001C9S-7UX FVR002C9S-7UX FVR-C9S-7UX Field wiring connection shall be made by a UL listed and CSA Certified closed-loop terminal connector sized for the wire gauge involved.
Connector must be fixed using the crimp tool specified by the connector manufacturer. • (Permissible voltage: AC220V - 240V) 2.
Do not connect power supply to the drive output terminals (U, V, W). Connect power supply only to the power terminals (L1, L2) 3.
Doom 2 Full Torrent. • 3) This applies to the case where momentary power failure occurs under such conditions that rated voltage is inputted and load factor is 85%. 4) Shows the case where an applicable motor equipped with an AC reactor (option) on the input side is used. FVR-C9S-7UX [Hp] [kVA] 0.27. • Environment Vibration Storage temperature Atmospheric pressure Enclosure Cooling method 5) This indicates average braking torque of a single motor.
(Value varies according to motor efficiency. FVR-C9S-7UX [Hp] Key operation: Setting with UP/DOWN keys Potentiometer: Terminal for 1-5K ohm VR is provided. • 2 - 0.20 X 0.24 (2 - 5 X 6.2) 0.39 (10) 2.36 (50) Rated Current Type FVRF12C9S-7UX FVRF25C9S-7UX FVRF50C9S-7UX FVR001C9S-7UX FVR-C9S-7UX 0.24 (6.2) 0.26 (6.5) 0.43 (11) 0.06 (1.5) 0.39 (10) DWG 1: FVRF12C9S-7UX to FVROO1C9S-7UX External Dimensions: inches (mm) 0.66 3.37 (85.5) 0.89 (22.5) • 3.86 (98) 2 - dia. 0.20 (2 - dia. 5) 0.20 (5) 0.45 (11.5) 3.43 (87) Rated Current Type FVR002C9S-7UX FVR-C9S-7UX 0.24 (6.2) 0.24 (6.2) 0.18 (4.5) 0.43 (11) 0.45 (11.5) DWG 2: FVR002C9S-7UX External Dimensions: inches (mm) 5.53 (140.5) 3.05 (77.5) • Space: The drive will generate heat during operation. Allow sufficient space around the unit as shown in the above figure.
FVR-C9S-7UX Mounting plate: Heat sink temperature will reach +90 C during operation. Please use thermostable material for drive mounting plate. • CN2 on the drive main unit are connected. FVR-C9S-7UX Note 3) Connect the power supply of over Disconnect CN 1 CN 2 5) Reinstall the cover.
Connect the harness CRG Lamp. • STOP keys on the keypad panel. Power Supply AC220 - 240V 50/60 Hz 1-phase * PE terminal blocks for the drive and motor should be provided in the cabinet in which the drive is installed in. FVR-C9S-7UX 8 8 8 10V 1mA E(G) Fault. • * PE terminal blocks for the drive and motor should be provided in the cabinet in which the drive is installed in. FVR-C9S-7UX Thermal Relay 8 8 8. • Listed fuse* * The use of quick-acting fuses is required to validate UL listing.
The factory recommendation is Bussman type JKS or equivalent. FVR-C9S-7UX Long wiring lengths between the motor and the drive will result in increased capacitance and leakage current. This may cause earlier. • Grounding terminal of drive chassis (case). Be sure to ground the drive to prevent electric shock or to lower noise Used as a power supply for frequency setter (variable resistor: 1 - 5K ohm) (DC + 10V, 10mA max) DC 0 - +10V / 0 - 100% (Input resistance: 22K ohm) • Output for Motor Contact 30A, B, C Output FVR-C9S-7UX Terminal Name Outputs + 10VDC between FM and CM terminals.